Functional Limits
Hard Limits
The following hard limits are designed into Tecplot 360. Your workstation’s memory may, however, not always be sufficient to allow the product to reach these limits.
Item | Limit |
---|---|
Maximum number of data points per data set |
Quintillions (limited by memory) |
Maximum number of data points per zone |
Quintillions (limited by memory) |
Largest floating point absolute value |
10150 |
Smallest non-zero floating point absolute value |
10-150 |
Maximum number of datasets |
2048 |
Maximum number of zones |
More than 2 billion |
Maximum number of variables |
More than 2 billion |
Maximum number of frames |
2048 |
Maximum number of pages |
2048 |
Maximum number of macro variables |
400 |
Maximum number of value blank constraints |
8 |
Maximum number of contour groups |
8 |
Maximum number of geometries |
Limited only by memory |
Maximum number of polylines per line geometry[1] |
50 |
Maximum number of points per circle or ellipse |
720 |
Maximum number of custom label sets |
Limited only by memory |
Maximum number of custom labels per set |
5000 |
Minimum frame width or height |
0.1 inches |
Maximum frame width |
500 inches |
Maximum streamtraces per frame |
32,000 |
Maximum number of streamtrace steps |
10,000 |
Maximum number of color map overrides |
16 |
Maximum preview width for EPS files |
1024 |
Maximum preview height for EPS files |
1024 |
Maximum number of user-defined color map control points |
50 |
Maximum number of raw user-defined color map entries |
800 |
Maximum number of characters in variable name |
128 |
Maximum number of characters in zone title |
128 |
Maximum number of characters in dataset title |
256 |
Maximum number of views per view stack |
16 |
Maximum number of characters in an auxiliary data string |
32,000 |
Line length limit in ASCII .dat files (character limit per line) |
32,000 |
Item | Limit |
---|---|
Printing Gouraud shaded plots with continuous flooding |
On screen or exported bitmap image only |
Printing plots with translucency |
On screen or exported bitmap image only |
Soft Limits
The following soft limits may be changed by editing your Tecplot 360 configuration file. The configuration file, tecplot.cfg, is installed in your Tecplot 360 home directory.
Limit | Soft Limit | Hard Limit | Macro Parameter |
---|---|---|---|
Points per line[2] |
20000 |
Quintillions |
MAXPTSINALINE |
Contour levels |
150 |
5,000 |
MAXNUMCONTOUR |
Characters per text label |
16,000 |
100,000 |
MAXCHRSINTEXTLABELS |
Picked objects |
1500 |
More than 2 billion |
MAXNUMPICKOBJECTS |
Load on demand - min threshold |
0.3 |
0[3] |
LODTHRESHOLDMINFRACT |
Load on demand - max threshold |
0.7 |
1 |
LODTHRESHOLDFRACT |
Available processors |
0[4] |
64 |
MAXAVAILABLEPROCESSORS |