Functional Limits
Hard Limits
The following hard limits are designed into Tecplot 360. Your workstation’s memory may, however, not always be sufficient to allow the product to reach these limits.
| Item | Limit |
|---|---|
Maximum number of data points per data set |
Quintillions (limited by memory) |
Maximum number of data points per zone |
Quintillions (limited by memory) |
Largest floating point absolute value |
10150 |
Smallest non-zero floating point absolute value |
10-150 |
Maximum number of datasets |
2048 |
Maximum number of zones |
More than 2 billion |
Maximum number of variables |
More than 2 billion |
Maximum number of frames |
2048 |
Maximum number of pages |
2048 |
Maximum number of macro variables |
400 |
Maximum number of value blank constraints |
8 |
Maximum number of contour groups |
8 |
Maximum number of geometries |
Limited only by memory |
Maximum number of polylines per line geometry[1] |
50 |
Maximum number of points per circle or ellipse |
720 |
Maximum number of custom label sets |
Limited only by memory |
Maximum number of custom labels per set |
5000 |
Minimum frame width or height |
0.1 inches |
Maximum frame width |
500 inches |
Maximum streamtraces per frame |
32,000 |
Maximum number of streamtrace steps |
10,000 |
Maximum number of color map overrides |
16 |
Maximum preview width for EPS files |
1024 |
Maximum preview height for EPS files |
1024 |
Maximum number of user-defined color map control points |
50 |
Maximum number of raw user-defined color map entries |
800 |
Maximum number of characters in variable name |
128 |
Maximum number of characters in zone title |
128 |
Maximum number of characters in dataset title |
256 |
Maximum number of views per view stack |
16 |
Maximum number of characters in an auxiliary data string |
32,000 |
Line length limit in ASCII .dat files (character limit per line) |
32,000 |
| Item | Limit |
|---|---|
Printing Gouraud shaded plots with continuous flooding |
On screen or exported bitmap image only |
Printing plots with translucency |
On screen or exported bitmap image only |
Soft Limits
The following soft limits may be changed by editing your Tecplot 360 configuration file. The configuration file, tecplot.cfg, is installed in your Tecplot 360 home directory.
| Limit | Soft Limit | Hard Limit | Macro Parameter |
|---|---|---|---|
Points per line[2] |
20000 |
Quintillions |
MAXPTSINALINE |
Contour levels |
150 |
5,000 |
MAXNUMCONTOUR |
Characters per text label |
16,000 |
100,000 |
MAXCHRSINTEXTLABELS |
Picked objects |
1500 |
More than 2 billion |
MAXNUMPICKOBJECTS |
Load on demand - min threshold |
0.3 |
0[3] |
LODTHRESHOLDMINFRACT |
Load on demand - max threshold |
0.7 |
1 |
LODTHRESHOLDFRACT |
Available processors |
0[4] |
64 |
MAXAVAILABLEPROCESSORS |